387-021
|
Loosening and Migration of Acetabular Cup into Pelvis
J. Jírová, M. Micka, J. Jíra, A. Sosna, and D. Pokorný (Czech Republic)
|
Abstract
|
|
387-024
|
Risk Factors for Knee Osteoarthritis: A Review of Epidemiological Studies
C.C. Norman and T.A. Kress (USA)
|
Abstract
|
|
387-041
|
Biomechanical Evaluation of a Double-bundle Technique for the Reconstruction of the ACL
G. Papachristou, J. Sourlas, and E.A. Magnissalis (Greece)
|
Abstract
|
|
387-044
|
Measurement of the Micromotion and Migration of an Un-cemented Stem in an In-vitro Test
J.P. Clements, S. Gheduzzi, J. Heal, I.D. Learmonth, and A.W. Miles (UK)
|
Abstract
|
|
387-054
|
A New Designed Acetabular Cup - Initial Strength Evaluation using Finite Element Analysis
D.Y. Jung, S. Tsutsumi (Japan), R. Sekel, R. Frost (Australia), K. Ikeuchi (Japan), and P.
|
Abstract
|
|
387-055
|
Study of the Motion Analysis for Total Knee Arthroplasty using Flat Panel Detector
T. Shimoto, H. Higaki, T. Fukunaga, S. Yasutake, Y. Nakanishi, H. Miura, T. Mawatari, and Y. Iwamoto
|
Abstract
|
|
387-057
|
Analyzis of a New Femur Lengthening Surgery
Z. Zörgő, A. Hajdu, S. Manó, Z. Csernátony, and S. Molnár (Hungary)
|
Abstract
|
|
387-094
|
Development of Simulated Implantation System for Artificial Hip Joint based on Biomechanical Analysis using Finite Element Model
Y.H. Kim, J.K. Kim, J.K. Kim, and K. Choi (Korea)
|
Abstract
|
|
387-005
|
Active Finite Element Analysis of Muscle-tendon Complex
C.P. Tsui, C.K. Li, C.P. Leung, Y.F. Ng, H.K. Chow, K.W. Cheng, and C.Y. Tang (PRC)
|
Abstract
|
|
387-025
|
The United States Postal Service Dynamic Ergonomic Analysis Tool (DEAT)
T.A. Kress, R.L. Kress, L. Elyea, C. Schiappacasse, and K. Rider (USA)
|
Abstract
|
|
387-032
|
Research of Impact Dynamic System of Tactile Device Transmitted Information to Human Sensory Organs
M. Mariūnas and A. Šešok (Lithuania)
|
Abstract
|
|
387-062
|
Finite Element Modelling of Ultrasound Propagation in Fractured Long Bones
V. Protopappas, I. Kourtis, D.I. Fotiadis, and C.V. Massalas (Greece)
|
Abstract
|
|
387-081
|
On a New Technique for Generating Finite Element and Rapid Prototyped Models based on 3D Data
R. Füreder, T.B. West, V. Bùi Xuân, I. Weber, and P.G. Young (UK)
|
Abstract
|
|
387-086
|
Numerical and Experimental Analysis of the Mechanical Performance of the Mennen Femur Plate
C.A. Pappas, P.G. Young, and A.J.C. Lee (UK)
|
Abstract
|
|
387-102
|
A Fuzzy Logic Control Technique for Blood Glucose Level in Diabetics
M.S. Ibbini, M.A. Masadeh, and M.M. Bani Amer (Jordan)
|
Abstract
|
|
387-105
|
Bone Remodelling Around Orthodontically Loaded Dental Implants
P.M. Cattaneo, M. Dalstra (Denmark), F. Beckmann (Germany), and B. Melsen (Denmark)
|
Abstract
|
|
387-126
|
In-vitro Validation of a FEM Model for Craniofacial Effects during Rapid Maxillary Expansion
C. Provatidis, B. Georgiopoulos, A. Kotinas (Greece), and J.P. McDonald (UK)
|
Abstract
|
|
387-007
|
Human Posture Estimation Method from a 3D Surface Image using Fuzzy Logic Evaluation
M. Chalupova, A. Rysavkova, I. Pallova, and S. Otahal (Czech Republic)
|
Abstract
|
|
387-031
|
Pre- and Postoperative Temporal Gait Analysis of Female Hip Monoarthritic Patients Operated with Cementless Hip Replacement: A 3-Year Study
V. Kyriazis (Greece)
|
Abstract
|
|
387-040
|
Biomechanical Structure of the Arm Predicts Kinematic Invariants of Hand Movements
N. Dounskaia, C. Ketcham, and G. Stelmach (USA)
|
Abstract
|
|
387-045
|
Determining Mass Centre Trajectory Variations for Application to Human Modelling
R.H. Mitchell, A.I.T. Salo, and A.J. Medland (UK)
|
Abstract
|
|
387-058
|
The Influence of Chair Geometry on Sit-to-stand Forces
H.C. Turner, R.M. Yate, G.E.B. Giddins, and A.W. Miles (UK)
|
Abstract
|
|
387-068
|
Mechanical Loading of Hip Joint during Normal Gait
M. Sochor and Z. Horak (Czech Republic)
|
Abstract
|
|
387-107
|
Improvements in Measure-based Simulation of the Human Lower Extremity
A. Kecskeméthy, D. Strobach (Germany), G. Steinwender, B. Zwick, V. Saraph, and M. Stolz (
|
Abstract
|
|
387-109
|
Characterization of Quadruped Gait
J. Lee (USA)
|
Abstract
|
|
387-022
|
Fault Tree Analysis for Assessing Propeller Guard Injury Prevention Effectiveness
T.A. Kress and R.L. Kress (USA)
|
Abstract
|
|
387-034
|
Reproducing Biomechanical Cervical Phenomena in Low-speed Rear-end Collisions by K-D Neck Model®
M. Tanaka, H. Yoshida, and S. Tsutsumi (Japan)
|
Abstract
|
|
387-080
|
A Real-time Monitoring Platform for Assessing Rehabilitation of the Lower Extremities in Athletes
C. Glaros, D.I. Fotiadis, A. Likas, M. Hantes, and A. Stafylopatis (Greece)
|
Abstract
|
|
387-083
|
The Influence of Projectile Mass and Velocity on the Response of the Brain to Blunt Impact
S.R. Rodriges, E.A.C. Johnson, and P.G. Young (UK)
|
Abstract
|
|
387-097
|
Hybrid III Chest Response to Simulated Projectiles and Hand-held Weapon Threats Representative of Crowd Management Scenarios
I. El Maach, C. Kessler, J.P. Dionne, A. Makris, and B. Anctil (Canada)
|
Abstract
|
|
387-098
|
Comparison of the Performance of Two Chest Protector Types when Impacted with a Baseball Bat
I. El Maach, C. Kessler, J.P. Dionne, and A. Makris (Canada)
|
Abstract
|
|
387-108
|
Simulating Ligament Injury or Laxity
J. Lee (USA)
|
Abstract
|
|
387-800
|
Numerical
Human Model for Impact and Seating Comfort
J. van Hoof, R. de Lange, and M. Verver (The Netherlands)
|
Abstract
|
|
387-019
|
Multifingers Manipulation Modeling with Thumb Abduct-opposed Motions under Muscle Activations
T. Tsuta, T. Iwamoto, T. Nakaya, and K. Ishikawa (Japan)
|
Abstract
|
|
387-033
|
Stretch Tolerance Following an Acute Straight Leg Raise Stretching Intervention
M. Zito, D. Tiberio, and P.J. Brennan (USA)
|
Abstract
|
|
387-047
|
Experimental Verification of Viscoelastic Properties of Compact Bone
M. Petrtýl, L. Melzerová, J. Danešová, and A. Wohlmuthová (Czech Republic)
|
Abstract
|
|
387-061
|
Does the Minimum Energy Principle Govern Wrist Kinematics?
D.M. Sirkett, G. Mullineux, A.W. Miles, and G.E.B. Giddins (UK)
|
Abstract
|
|
387-110
|
A Generic
Anatomical Model of the Human Mandible
Y.F. Lam, D.F. Gillies, D. Rueckert, P. Charters,
P. Groom, and S. Roughley (UK)
|
Abstract
|
|
387-020
|
How Normal is Cartilage that Looks Normal?
R. Flachsmann, W. Kim, and N.D. Broom (New Zealand)
|
Abstract
|
|
387-026
|
Mechanical Characterization of Urinary Bladder during Filling Phase
F. Moravec, M. Müller, V. Nováček, and P. Pechmanová (Czech Republic)
|
Abstract
|
|
387-027
|
Measurement of Material Properties of Cancellous Bone using Small Specimens and Optical Identification Method
O. Jiroušek, J. Jírová, and D. Vavřík (Czech Republic)
|
Abstract
|
|
387-036
|
Investigation of the Influence of Endoprostheses Material Properties Upon the Distribution of the Pressure and the Wear in the Contact Surface
M. Mariūnas and J. Karavackaitė (Lithuania)
|
Abstract
|
|
387-039
|
Modelling Soft Tissue Deformations using Principal Component Analysis and Haptic Devices
D.F. Gillies and M. Bourmpos (UK)
|
Abstract
|
|
387-048
|
Smooth Muscle Tissue Mechanical Properties - Material Models
R.M. Pidaparti, P.A. Sarma, and R.A. Meiss (USA)
|
Abstract
|
|
387-063
|
On the Non-destructive Determination of the Mechanical Response State in Biomaterials: A Pattern Recognition and Classification Approach
Y.M. Haddad (Canada)
|
Abstract
|
|
387-067
|
Composites based on Glass Fibres and Siloxane Matrix as a Promising Biomaterial
M. Sochor, K. Balik, T. Suchy, H. Hulejova, and V. Pesakova (Czech Republic)
|
Abstract
|
|
387-106
|
Microtomography of Cortical Bone using a Synchrotron Source
M. Dalstra, P.M. Cattaneo (Denmark), F. Beckmann (Germany), and E.M. Hauge (Denmark)
|
Abstract
|
|
387-112
|
Hydrodynamic Characterisation of the Decellularised Intact Porcine Aortic Valve
S. Korossis, H. Wilcox, K. Watterson, J. Kearney, E. Ingham, and J. Fisher (UK)
|
Abstract
|
|
What are Digital Object Identifers?