SINGLE-PHASE INDUCTION GENERATOR FEEDING AN IDENTICAL SINGLE-PHASE INDUCTION MOTOR

Y.N. Anagreh

References

  1. [1] S. Murthy, O. Malik, & A. Tandon, Analysis of self-excitedinduction generators, IEE Proc. Pt. C., 129 (5), 1982, 260–265.
  2. [2] A. Alolah & M. Alkanhal, Optimization-based steady stateanalysis of three phase self-excited induction generator, IEEETrans. on EC, 15 (1), 2000, 61–65. doi:10.1109/60.849117
  3. [3] Y. Rahim, A. Alolah, & R. Al-Mudaiheem, Performance ofsingle phase induction generators, IEEE Trans. on EC, 8(3),1993, 389–395. doi:10.1109/60.257050
  4. [4] O. Ojo & I. Bhat, An analysis of single-phase self-excitedinduction generators: Model development and steady-statecalculations, IEEE Trans. on EC, 10(2), 1995, 254–260. doi:10.1109/60.391890
  5. [5] B. Singh, S. Murthy, & S. Gupta, Analysis and implementationof an electronic load controller for a self-excited inductiongenerator, IEE Proc. Generation, Transmission & Distribution,151(1), 2004, 51–60. doi:10.1049/ip-gtd:20040056
  6. [6] D. Seyoum, C. Grantham, & M. Rahman, The dynamiccharacteristics of an isolated self-excited induction generatordriven by a wind turbine, IEEE Trans. on IA, 39(4), 2003,936–944. doi:10.1109/TIA.2003.813738
  7. [7] T. Chan & L. Lai, A novel excitation scheme for a stand-alonethree-phase induction generator supplying single phase loads,IEEE Trans. on EC, 19(1), 2004, 136–143. doi:10.1109/TEC.2003.822299
  8. [8] S. Murthy, A novel self-excited self-regulated single phaseinduction generator, Part 1: Basic system and theory, IEEETrans. on EC, 8(3), 1993, 377–382. doi:10.1109/60.257048
  9. [9] S. Murthy, C. Nagamani, & K. Satyanarayana, Studies on theuse of conventional induction motors as self-excited inductiongenerator, IEEE Trans. on EC, 3(4), 1988, 842–847. doi:10.1109/60.9360
  10. [10] B. Sinph & L. Shilpkar, Steady-state analysis of single-phaseself-excited induction generator, IEE Proc. Generation, Transmission & Distribution, 146(5), 1999, 421–427.AppendixEach machine used in the present work has the followingrated values: 230 V, 0.75 kW, 6 A, 50 Hz, 3000 rpm. Theequivalent circuit parameters in p.u. are:R1mM /R1mG = 0.104 R1aM /R1aG = 0.143R2M /R2G = 0.0835 a = 1.17X2M /X2G = 0.12 X1mM /X1mG = 0.12X1aM /X1aG = 0.18 XmuM /XmuG = 6.13273Csh, and Crun, are 30 µF and 5 µF, respectively. Therelationship between the forward component of the air-gapvoltage and the magnetizing reactance is approximated by:Egff= −0.0044X3m − 0.0034X2m + 0.0273Xm + 1.45 doi:10.1049/ip-gtd:19990607

Important Links:

Go Back